Lippert-components 3 X 3 Slideout System User Manual

Browse online or download User Manual for Hardware Lippert-components 3 X 3 Slideout System. Lippert Components 3 X 3 Slideout System User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - 3 X 3 SLIDEOUT SYSTEM

3 X 3 SLIDEOUT SYSTEMOPERATION AND SERVICE MANUAL

Page 2 - TABLE OF CONTENTS

SERVICETROUBLESHOOTINGThe Lippert 3 x 3 Slideout System is only one of four interrelated slideoutroom system components. These four components are as

Page 3 - DESCRIPTION

The Lippert 3 x 3 Slideout System can be timed and fine-tuned foroptimum performance. In the event the travel of either side of this two-rail system

Page 4 - PRIOR TO OPERATION

TROUBLESHOOTING CHARTThe following troubleshooting chart outlines some common problems, their causes andpossible corrective actions. When reference i

Page 5 - OPERATION

13Switch related problems:• If room moves opposite from what the switch plate indicates, reversethe motor wires on the back of the switch (refer to th

Page 6 - Wall Switch

14 BATTERY MOTOR RED CHANGE OF POLARITY REVERSES MOTOR GREEN MOTOR 10 GA WIRE MINIMUM 30A AUTO RESET BREAKER LOCATE WITHIN 18” OF BATTERY IN

Page 7 - RETRACTING SLIDEOUT ROOM

15ORDERING PARTSTo assist the customer service when ordering parts, please provide thefollowing information:1. Your Name2. Company Name3. Phone

Page 8 - MANUAL OPERATION

SYSTEM……………………………………………...….…..Warning…………………………………...……...Description………………………………...……..Prior to Operation……………………...………OPERATION

Page 9 - PREVENTATIVE MAINTENANCE

SYSTEMWARNINGFAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWINGMAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH.The Lippert 3 x 3 Slideout System is intend

Page 10 - TROUBLESHOOTING

Disassembly of the motor voids the warranty.Mechanical portions of the slideout system are replaceable. ContactLippert Components, Inc. to obtain rep

Page 11

OPERATIONMAIN COMPONENTSMECHANICAL Fig. 1 5

Page 12 - TROUBLESHOOTING CHART

Fig. 3 Switch Plate “IN” Slideout Operation “OUT” Slideout Operation SPOT Momentary Switch CAUTION! – The wall switch operates on high voltage. Exe

Page 13 - TROUBLESHOOTING – MOTOR

OPERATING SYSTEMWARNINGFAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAYRESULT IN SERIOUS PERSONAL INJURY OR DEATH.ALWAYS MAKE SURE THAT THE SLIDEOU

Page 14 - HIGH VOLTAGE

MANUAL OPERATION8 B C Fig. 41. Prior to Manual Operation, be sure to clear any obstruction from theslideout area that may impede the extension or retr

Page 15 - ORDERING PARTS

PREVENTATIVE MAINTENANCEThe Lippert 3 x 3 Slideout System has been designed to require verylittle maintenance. To ensure the long life of your slideo

Comments to this Manuals